Traceable,NIST,ISO 17025,A2LA,aerosol,anemometers,barometers,battery tester,burn stations,calculators,calipers,carts,clamps,clocks,conductivity,controllers,counters,data logger,desiccants,electrode arm,glassware tools,humidity,lasers,lights,light meters,liquid alarm,magnifiers,moisture,multimeters,oxygen meters,pens,graphs,pressure,vacuum,pumps,slide holder,software,sound meters,stopwatches,tachometers,tags,thermometers,timers,tools,wash bottles,wipes,weather station,pumps,peristaltic  
Home | About Us | Contact | Technical | Dealers | Instructions | MSDS | Order Cat.
Recalibration | Service | Salary Data

Products
Anemometers
Barometers
Battery Tester
Burn Stations
Calculators
Calipers
Carts
Clamps
Clocks
Conductivity
Controllers
Counters
Data Logger
Desiccants
Desiccators
Duster
Electrode Arm
Glassware Tool
Humidity
Lasers
Lights
Light Meter
Liquid Alarm
Manometers
Magnifiers
Moisture
Multimeters
Oxygen Meter
Pens/Graphs
Pressure/Vac
Pumps
Slide Holder
Software
Sound Meter
Stopwatches
Tachometers
Tags
Thermometers
Timers
Tools
Wash Bottles
Wipes
Weather Station
Free Samples
Clamps
Desiccant
Humidity Card
Slide Holder

  3460-3469
  Traceable® Manometer/Pressure/Vacuum Gauge
  • Memory feature
  • Computer output
  • Printing and Non-Printing models
 
Starting at $ 168.33
Specifications: See specification chart below 

Traceable® Manometer/Pressure/Vacuum Gauge Complete Description

Manometer displays gauge and differential pressure/vacuum in eleven different units. Response time is 0.5 second. Simple hose fittings on the unit permit using hose/tubing with inside diameters from 1/16 to 3/16 inches. Large 5/8-inch-high digits are visible from six feet.

At the touch of a button unit may be zeroed or any pressure may set to zero. Differential feature permits reading the difference of the pressure or vacuum between two different sources. Memory feature recalls highest and lowest reading over any time period. A count-up timer displays up to 99 hours, 59 minutes, 59 seconds. A DATA HOLD key freezes the display to capture readings. Brilliant backlighting permits reading even in dark areas. Computer output permits all units to be connected to a computer for monitoring and storing unlimited results. Accuracy is ±0.3% of full scale between 0 to 50°C. To assure accuracy an individually serial-numbered Traceable® Certificate is provided from our ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology).

Printing model
Data logging feature permits automatically capturing and storing up to 12,000 readings, including date and time at intervals as short 1 second or as long as 2 hours. Printing model allows the user to manually capture and store up to 99 readings, including date and time at the press of a button. Printer provides a hard copy for today’s stringent quality-control documentation. Printer model prints samples number, current reading, date, and time. Printer allows both manual memories and data logger memories to be printed without the need for a computer. Printing/data logging model is supplied with Traceable® Certificate, hose/tubing, AA batteries, ABS plastic carrying case, and paper roll. Size is 2-3/4 x 8 x 1-3/4 inches and weight is 12 ounces. Replacement battery Cat. No. 1111 (4 each).

Non-printing model
Non-printing model is supplied with Traceable® Certificate, hose/tubing, 9-volt battery, computer output, and ABS plastic carrying case. Computer output allows current programmable capturing to be streamed to a pc computer (computer cable and software not supplied, requires accessory 8045). Size is 2-3/4 x 7-1/8 x 1-1/8 inches and weight is 5 ounces. Replacement battery Cat. No. 1112.

Traceable® Manometer/Pressure/Vacuum Gauge

Cat. No. (Non-Printing) 3460 3461 3462 3463
Cat. No. (Printing/Datalogging) 3466 -- -- 3469
Maximum Allowed PSI 20 30 60 150
PSI Range –5.000 to 5.000 –15.00 to 15.00 –30.00 to 30.00 –100.0 to 100.0
PSI Resolution 0.003 0.01 0.02 0.1
mbar Range –345.0 to 345.0 –1034 to 1034 –2068 to 2068 –6895 to 6895
mbar Resolution 0.2 1 2 4
bar Range –0.3450 to 0.3450 –1.034 to 1.034 –2.068 to 2.068 –6.895 to 6.895
bar Resolution 0.001 0.001 0.002 0.004
cm/H2O Range –351.0 to 351.0 –1055 to 1055 –2109 to 2109 –7031 to 7031
cm/H2O Resolution 0.2 1 2 4
inch/H2O Range –138.0 to 138.0 –415.0 to 415.0 –830.0 to 830.0 –2768 to 2768
inch/H2O Resolution 0.1 0.3 0.5 2
feet/H2O Range –12.00 to 12.00 –35.00 to 35.00 –69.00 to 69.00 –231.0 to 231.0
feet/H2O Resolution 0.01 0.02 0.04 0.2
mm/Hg Range –259.0 to 259.0 –776.0 to 776.0 –1551 to 1551 –5171 to 5171
mm/Hg Resolution 0.2 0.5 1 3
inch/Hg Range –10.00 to 10.00 –31.00 to 31.00 –61.00 to 61.00 –204.00 to 204.00
inch/Hg Resolution 0.01 0.03 0.1 1.0
kg/cm2 Range –0.350 to 0.350 –1.060 to 1.060 –2.110 to 2.110 –7.030 to 7.030
kg/cm2 Resolution 0.001 0.001 0.002 0.004
oz/inch2 Range –80.00 to 80.00 –240.0 to 240.0 –480.0 to 480.0 –1600 to 1600
oz/inch2 Resolution 0.05 0.2 0.3 1
kPa Range –34.50 to 34.50 –103.0 to 103.0 –207.0 to 207.0 –690.0 to 690.0
kPa Resolution 0.02 0.1 0.2 0.4

ACCESSORY Cat. No. 8045 Data Acquisition System—79 inch computer cable and software on a CD . (accessory only for non-printing model)

Page updated on