Traceable,NIST,ISO 17025,A2LA,aerosol,anemometers,barometers,battery tester,burn stations,calculators,calipers,carts,clamps,clocks,conductivity,controllers,counters,data logger,desiccants,electrode arm,glassware tools,humidity,lasers,lights,light meters,liquid alarm,magnifiers,moisture,multimeters,oxygen meters,pens,graphs,pressure,vacuum,pumps,slide holder,software,sound meters,stopwatches,tachometers,tags,thermometers,timers,tools,wash bottles,wipes,weather station,pumps,peristaltic  
Home | About Us | Contact | Technical | Dealers | Instructions | MSDS | Order Cat.
Recalibration | Service | Salary Data

Products
Anemometers
Barometers
Battery Tester
Burn Stations
Calculators
Calipers
Carts
Clamps
Clocks
Conductivity
Controllers
Counters
Data Logger
Desiccants
Desiccators
Duster
Electrode Arm
Glassware Tool
Humidity
Lasers
Lights
Light Meter
Liquid Alarm
Manometers
Magnifiers
Moisture
Multimeters
Oxygen Meter
Pens/Graphs
Pressure/Vac
Pumps
Slide Holder
Software
Sound Meter
Stopwatches
Tachometers
Tags
Thermometers
Timers
Tools
Wash Bottles
Wipes
Weather Station
Free Samples
Clamps
Desiccant
Humidity Card
Slide Holder

  3650-3652
  Traceable® Vane Anemometer Pens
  • Compact design
  • Easy-to-use
  • MIN/MAX readings
 
Starting at $ 99.99
Specifications: See chart below 

Traceable® Vane Anemometer Pens Complete Description

Three units provide for airflow/temperature; airflow/temperature/humidity/dew point; and airflow/temperature/humidity/dew point/barometric pressure.

Easy to use rugged design
Simple operation eliminates the need to refer to instructions. Designed for intuitive, easy operation by everyone. Tough ABS plastic housing with O-ring seal and membrane keypad keep out dust and dirt, assuring a long life in severe lab or harsh plant environments. HOLD button freezes the reading on the display. High contrast 3/8-inch-high LCD digits are easy to read. At the press of a button, unit recalls minimum/ maximum readings.

Traceable to NIST
To assure accuracy an individually serial-numbered Traceable® Certificate is provided from our ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology). Rugged ABS plastic case is 1-1/2 diameter x 8-1/4 inches; weight is 6 ounces. Supplied with a Traceable® Certificate and four AAA batteries. Replacement battery Cat. No. 1105.

Control Company Cat. No. 3650 Traceable® Vane Anemometer/Thermometer Pen

Control Company Cat. No. 3651 Traceable® Vane Anemometer/Thermometer/Hygrometer/Dew Point Pen

Control Company Cat. No. 3652 Traceable® Vane Anemometer/Thermometer/Hygrometer/Dew Point / Barometer Pen

Specifications Chart
Cat. No. 3650 3651 3652
Air Flow Range 0.4 to 30.0 m/s
1.4 to 108.0 km/hr
80 to 5910 ft/min
0.9 to 67.0 mile/hr
0.8 to 58.3 knots
0.4 to 30.0 m/s
1.4 to 108.0 km/hr
80 to 5910 ft/min
0.9 to 67.0 mile/hr
0.8 to 58.3 knots
0.4 to 30.0 m/s
1.4 to 108.0 km/hr
80 to 5910 ft/min
0.9 to 67.0 mile/hr
0.8 to 58.3 knots
Air Flow Resolution 0.1 m/s
0.1 km/hr
1 ft/min
0.1 mile/hr
0.1 knots
0.1 m/s
0.1 km/hr
1 ft/min
0.1 mile/hr
0.1 knots
0.1 m/s
0.1 km/hr
1 ft/min
0.1 mile/hr
0.1 knots
Air Flow Accuracy ±3% full scale under 20 m/s
±4% full scale over 20 m/s
±3% full scale under 20 m/s
±4% full scale over 20 m/s
±3% full scale under 20 m/s
±4% full scale over 20 m/s
Temperature Range 0.0 to 50.0°C
32.0 to 122.0°F
0.0 to 50.0°C
32.0 to 122.0°F
0.0 to 50.0°C
32.0 to 122.0°F
Temperature Resolution 0.1° 0.1° 0.1°
Temperature Accuracy ±0.8°C ±0.8°C ±0.8°C
Humidity Range 10.0 to 95.0% 10.0 to 95.0%
Humidity Resolution 0.1% 0.1%
Humidity Accuracy ±3% ±3%
Dew Point Range –13.5 to 120.1°F
–25.3 to 48.9°C
–13.5 to 120.1°F
–25.3 to 48.9°C
Dew Point Resolution 0.1° 0.1°
Barometric Pressure Range 10.0 to 1100 hPa
7.5 to 825.0 mmHg
0.29 to 32.48 inHg
Barometric Pressure Resolution 0.1 and 1 hPa
0.1 mmHg
0.01 inHg
Barometric Pressure Accuracy ±4 hPa