Traceable,NIST,ISO 17025,A2LA,aerosol,anemometers,barometers,battery tester,burn stations,calculators,calipers,carts,clamps,clocks,conductivity,controllers,counters,data logger,desiccants,electrode arm,glassware tools,humidity,lasers,lights,light meters,liquid alarm,magnifiers,moisture,multimeters,oxygen meters,pens,graphs,pressure,vacuum,pumps,slide holder,software,sound meters,stopwatches,tachometers,tags,thermometers,timers,tools,wash bottles,wipes,weather station,pumps,peristaltic  
Home | About Us | Contact | Technical | Dealers | Instructions | MSDS | Order Cat.
Recalibration | Service | Salary Data | Employment

Products
Anemometers
Barometers
Battery Tester
Burn Stations
Calculators
Calipers
Carts
Clamps
Clocks
Conductivity
Controllers
Counters
Data Logger
Desiccants
Desiccators
Duster
Electrode Arm
Glassware Tool
Humidity
Lasers
Lights
Light Meter
Liquid Alarm
Manometers
Magnifiers
Moisture
Multimeters
Oxygen Meter
Pens/Graphs
pH Buffers
Pressure/Vac
Pumps
Slide Holder
Software
Sound Meter
Stopwatches
Tachometers
Tags
Thermometers
Timers
Tools
Wash Bottles
Wipes
Weather Station
Free Samples
Clamps
Desiccant
Humidity Card
Slide Holder

  4100, 4101
  Traceable® Printing Thermometer °F/°C
  • Permanent copy results
  • Programmable intervals from 23 hours and 59 minutes
  • MIN/MAX Memory
 
Starting at $ 488.16
Specifications: Range is –328 to 2431°F or –200 to 1333 °C · Resolution is 0.1° · Accuracy is ±1°C · Carrying case is 3-1/2 x 8 x 1-1/4 inches · Weight is 10 ounces 

Traceable® Printing Thermometer °F/°C Complete Description

Printing Thermometer provides permanent record, prints time and date
Provides permanent record of temperature and time of day/date/month. Unit prints the time and date for maximum only, minimum only, average only and in circularly mode T1, T2 and differential. Automatic printing may be programmed to print in any interval from 3 seconds to 23 hours 59 minutes 59 seconds. The perfect dependable and reliable unit to monitor temperature in lab, plant, and field. Fulfills federal requirements for CLIA specification 493.1252.

Hard copy results
Printer provides hard copy for today’s stringent quality-control documentation. Minimum, maximum, and average temperature memories may be displayed or cleared at any time with the touch of a button. Memory feature permits monitoring conditions overnight, on weekends, or for any time period. Alarm may be set in 0.1° increments. Alarm sounds when temperature rises above or falls below set points. Alarm output feature may be used to trigger an external device.

Wide range
Displays temperatures from –328 to 2431°F and –200 to 1333 °C with a resolution of 0.1° and an accuracy of ±1°C from –50 to 982 °C, otherwise ±1.5 °C. Dual probe inputs allow displaying the temperature of probe 1, probe 2, or the difference (delta) of probe 1 and 2. Supplied with two fast-response, Type-K beaded sensors with cable length of 4 feet. Thermometer will accept any Type-J, K, T or E probes. Display is updated every second.

Traceable to NIST for accuracy
To assure accuracy an individually serial-numbered Traceable® Certificate is provided from our ISO 17025 calibration laboratory accredited by A2LA. It indicates traceability to standards provided by NIST (National Institute of Standards and Technology). Supplied with two fast-response, Type-K beaded sensor, Traceable® Certificate, six AAA batteries, two thermal paper rolls (good for approximately 1400 printings per roll), and ABS carrying case. Supplied with paper, carrying case, and six AAA batteries. Accessory adaptor for continuous AC operation is available. Tough ABS plastic case is chemical- and shock-resistant. Unit is 7-1/2 x 3 x 1-1/2 inches. Weight is 10 ounces. Replacement battery Cat. No. 1105.

Control Company Cat. No. 4100 Traceable® Printing Thermometer

Control Company Cat. No. 4101 Traceable® Printing Thermometer

Cat. No. Accessories
8182 Replacement Printing Paper (pack of 2 rolls)